You can reach us from our sales offices and call center for all your requests.

Karmod Office and Living Containers come in different shapes and sizes. Suitable for different purposes. Knowing your container types gives you a headstart – and the best chances to make the right business decisions for you. That’s why we’re here giving you an overview of the different types of office and living containers. Different container types were standardized in 1986. Karmod regulations dictated that the 230x600cm container type and 300x700cm container type now were industry standards. Office and site container specifications can vary slightly from these figures listed below.  If your needs require exact measurements, please consult your office container building Technology sales representative.

Container technical specifications

Karmod Flat Pack Container Introduction Video

KARMOD CONTAINER TECHNICAL SPECIFICATIONS
TECHNICAL DATA
SEISMIC CONDITIONS (Seismic Zone 1) Effective ground acceleration coefficient: Ao = 0.40
CLIMATIC CONDITIONS Manufactured for climatic zones 1, 2 and 3.
SNOW LOAD 80 kg/m² (varies depending on the installation location).
WIND SPEED 75 km/h
WALL THERMAL TRANSMITTANCE (U-VALUE) 0,71 W/m².K
ROOF THERMAL TRANSMITTANCE (U-VALUE) 0,37 W/m².K
LIGHT GAUGE STEEL MATERIAL TS EN 10346 DX 51D+Z /DIN EN 10169
SHEET METAL MATERIAL Electrostatically painted galvanized sheet steel, RAL 9002 and RAL 1019.
PU (Polyurethane) Panel TS EN 13501-1
CHASSIS LOAD CAPACITY 200 kg/m² (for two-storey buildings, calculated in accordance with TS 498).
FLOOR
SYSTEM

The container's side chassis members and corner posts are made of specially bent, corrosion-resistant galvanized sheet steel using a weld-free, bolted system. The floor chassis is made from U and C profiles and assembled using bolted connections. The supporting ground must be level.
Ground Anchoring Against Wind Loads Ground anchoring hardware for wind resistance is optional and supplied upon customer request. The stated values apply only when the container is anchored to the ground. Ground anchoring is the customer's responsibility, and Karmod assumes no responsibility for this work.
FLOOR COVERING A 2 mm thick PVC floor covering is applied over 14 mm thick fibre cement or cement-bonded particleboard flooring panels.
WALLS
SYSTEM Specially profiled sandwich panel with a PU (polyurethane) core.
EXTERNAL AND INTERNAL SURFACE CLADDING Front and rear facings are 0.3 mm coil-coated, micro-profiled galvanized sheet steel.
WALL INSULATION Wall panels are made with sheet steel facings and a 50 mm thick PU core with a density of 42 kg/m³, using safe materials that provide full thermal insulation.
ROOF
ROOF SYSTEM Sandwich panel with a PU (polyurethane) core. SPECIAL THREE-RIB SANDWICH PANEL WITH CAPPED JOINTS.
ROOF INSULATION Three-rib roof panels with capped joints are made using safe materials, with 50 mm thick PU (polyurethane) insulation at a density of 42 kg/m³.
EXTERNAL AND INTERNAL SURFACE CLADDING Front and rear facings are 0.3 mm coil-coated, micro-profiled galvanized sheet steel.
DOORS
EXTERNAL DOOR A sheet steel door with sealing gaskets, made with a 1.2 mm frame and a 0.5 mm painted sheet steel door leaf. Resistant to impact and scratches. The door leaf is filled with 20 kg/m³ expanded polystyrene (EPS) foam for sound and thermal insulation.
INTERNAL DOOR A laminated MDF door is fitted to an electrostatically painted galvanized metal frame (1980 × 755 mm).
WINDOWS
WINDOW A PVC window measuring 890 × 1135 mm is fitted. It has a single sash that opens to 90 degrees.
WINDOW TRIM Windows use U-shaped PVC frames.
GLAZING Double-glazed ISICAM insulating glass units are used.
PAINT FINISHES
EXTERIOR AND INTERIOR SURFACES RAL 9002 ELECTROSTATICALLY PAINTED SHEET STEEL.
METAL COMPONENTS RAL 1019 ELECTROSTATICALLY PAINTED SHEET STEEL.
ELECTRICAL INSTALLATION
SYSTEM AND CABLES System: surface-mounted. TSE-certified NYM cables are used: 3 × 2.5 for sockets, 2 × 1.5 for lighting and 3 × 1.5 for two-gang light switches.
LIGHTING TSE-certified globe light fittings with a single lamp holder are used.
SOCKETS AND SWITCHES Each room has a socket and a switch. A telephone socket is optional.
PLUMBING
SYSTEM Surface-mounted plumbing with hot and cold water connections as standard.
ABS Plastic Squat Toilet Pan Glossy, fibre-reinforced ABS squat toilet pans are used in WC containers to provide watertightness.
Toilet and Cistern TSE-certified ceramic toilets with rear outlets are used. Plastic cisterns are used in the WCs.
SHOWER TRAY TSE-certified square acrylic shower trays are used. (Shower trays are not installed in WC/shower containers.)
WASHBASIN TSE-certified ceramic products are used. Pedestal washbasins are used in WC and shower containers.
WATER SUPPLY PIPING TSE-certified PPRC materials are used.
WASTEWATER PIPING TSE-certified PVC materials are used.
ACCESSORIES TSE-certified accessories are used, including mirrors, hooks, metal toilet roll holders and plastic liquid soap dispensers.
WC AND SHOWER
VENTILATION Shower curtains are fitted at shower entrances. Ventilation grilles measuring 250 × 250 mm are used for showers and WCs. Corridors have two hopper windows measuring 600 × 400 mm, fitted on opposite side walls (the short sides).
FLOOR AND WALL COVERING The entire shower floor and the walls up to a minimum height of 1300 mm are covered with PVC floor covering, excluding partition walls. WC walls are covered with PVC floor covering up to a minimum height of 300 mm, excluding partition walls. PVC floor covering is also used on WC floors. Water supply pipes are enclosed with metal covers.
DOOR
(KAPI)
An outward-opening door, 700 mm or 900 mm wide, is used at the WC entrance.
LIGHTING LED lighting is used in the corridors.
SHIPPING
Lifting is made with specially designed brackets and columns.
Karmod Container Building Technologies has the right to make modifications in the Technical Specifications