TECHNICAL SPECIFICATIONS OF KARMOD PANEL CABIN | |
TECHNICAL DATAS | |
EARTHQUAKE CONDITIONS | 1st degree earthquake zone |
CLIMATE CONDITIONS | 3rd climatic zone |
SNOW LOAD | 80 Kg/m² |
WIND SPEED | 80 km/h (on condition that product is fixed on the ground) |
METALLIC MATERIALS | ST 37 GALVANIZED METAL PROFILE |
EXPANDED POLYSTYRENE FOAM | TS EN 13163 |
EXTERIOR WALL TRANSMISSION COEFFICIENT | 0,46 W/m²K |
ROOF TRANSMISSION COEFFICIENT | 0,26 W/m²K |
BASE TRANSMISSION COEFFICIENT | 1,24 W/m²K |
GROUND LOAD CAPACITY | 200 Kg/m² |
BASE | |
SYSTEM | The floor is applied on steel construction and galvanized single-piece box profiles. The ground to be placed must be level. |
Fixing ground against wind speed | It must be fixed on the ground against wind speed. The ground fixing device is optional. |
Base Cover | 2 mm thick PVC mineflo is applied on 14 mm thick cementboard . |
WALL | |
SYSTEM | The assembly is done by combining specially shaped EPS filled sandwich panels to the corner posts. |
Exterior Surface Coating | Exterior Surface Coatings are RAL 9002 electrostatic painted sheet. |
/ Interior Surface Coating | Interior Surface Coatings are RAL 9002 electrostatic painted sheet. |
Wall Insulation | It is made with E fire class, heat insulated, healthy and safe materials, using 40 mm thick polystyrene foam (EPS). |
ROOF | |
SYSTEM | The new system has a trapezoidal roof and glass wool insulation. A double-walled GRP roof panel with 42 density polyurethane foam is used in 135X135 and 135X210 dimensions. |
Roof Insulation | For t trapezoidal roof style 80 mm mineral wool or glass wool is used. For GRP roof panel 42 density polyurethane foam is used . |
Exterior Surface Coating | Natural trapeze or GRP roof panel |
Interior Surface Coating | PVC Panelling, or GRP roof panel |
DOORS | |
OUTER DOOR | The outer door is PVC door with special hinged espagnolette lock in white color. TSE certified locks and special door handles are used. |
WINDOWS | |
WINDOW | The window consists of electrostatic powder painted white aluminum profile frames. |
WINDOWPANE | 4 mm thick tempered glass (auto glass) is used on the windows of the cabin. It is produced in a way that will not damage aynone when glass is broken. |
PAINTS | |
Exterior and Interior Wall | RAL 9002 Electrostatic painted sheet |
Corner Junction Bracket | RAL 7043 (Patented 3-joint brackets are used in 135X135 and 135X210 cabins.) |
Corner Post | RALL 1019 electrostatic powder coated sheet (in 135X135 and 135X210 cabins, corner posts are exturised PVC RALL 7043 color.) |
ELECTRIC WIRING | |
SYSTEM | Surface mounted |
CABLE | 3*2,5 mm NYM TSE certificated cable is used for sockets. 2*1,5 mm NYM TSE certificated cable is used for lightening . |
LIGHTENING | TSE certificated fixtures are used. |
SANITARY INSTALLATIONS | |
SYSTEM | It is surface mounted and PPRC featured material is used. |
TOILET | Ceramic toilet, acrylic one piece ground stone is used. Ceramic ground stone is optional. TSE certified products are used. |
SHOWER TRAY | It is acrylic based and TSE certificated products are used. (Shower tray is not used in wc-shower containers.) |
SINK | Ceramic based and TSE certificated products are used. |
CLEAN WATER SYSTEM | TSE certificated PPRC featured materials are used. |
WASTE WATER SYSTEM | TSE certificated PVC featured materials are used. |
ACCESSORIES | TSE certified materials are used in products such as mirrors, hangers, metal paper holders, plastic liquid soap. |
WC-SHOWER VENTILATION | Grilles are used as shower and WC ventilation. |
OUTER CONNECTIONS | |
It is the customer's responsibility to lay concrete more than 20 cm above the cabin dimensions, to install the cabin on the ground, and to make electricity, clean water and waste water connections. Karmod Prefabricated Building Technologies Has the Right to Make Changes in Technical Specifications. |
|
Karmod has the right to make any changes in technical specifications. |