You can reach us from our sales offices and call center for all your requests.
METROPOL CABIN TECHNICAL SPECIFICATIONS
PRODUCTION DIMENSIONS Can Be Specially Produced On Demand.
HEIGHT 2800 mm Parapet Included.
METAL MATERIALS ST 37
BETOPAN TSE 634-2
GLASS WOOL TS 901
POLYSTREN FOAM TS EN 13163
TECHNICAL DATA
EARTHQUAKE CONDITIONS 1st degree
CLIMATE CONDITIONS 3. Climate Zone
SNOW LOAD 80 Kg/m²
WIND SPEED 80 Km/Hour (provided that it is fixed to the ground)
EXTERNAL WALL TRANSMISSION COEFFICIENT K: 0.50 Kcal/m2hc
ROOF TRANSMISSION COEFFICIENT K: 0.69 Kcal/m2hc
BASE HEAT CONDUCTION COEFFICIENT K: 0.68 Kcal/m2hc
CHASSIS LOAD CAPACITY 200 Kg/m²
BASE
FLOOR COATING PVC Mineflo with 2 mm thickness is used as floor covering on 14 mm non-flammable Betopan boards as the floor covering.
OUTER WALL
SYSTEM It is made with carcass with the help of specially shaped profiles.
EXTERIOR COATING The outer surface coating is optionally covered with 12 mm thick Taşonit or wood patterned concrete boards.
INTERNAL SURFACE COATING The inner surface coating is 8 mm thick betopan (inner surface coating PVC paneling is used in metropolitan cabins with WC).
WALL INSULATION 40 mm thick, 10 kg/m³ polystyrene foam (EPS) with fire class E; It is made with heat-insulated complete, healthy and safe materials.
INNER WALL
SYSTEM It is made with carcass with the help of specially shaped profiles.
INTERNAL SURFACE COATING The inner surface coating is 8 mm thick betopan (inner surface coating PVC paneling is used in metropolitan cabins with WC).
WALL INSULATION 40 mm thick, 10 kg/m³ polystyrene foam (EPS) with fire class E; It is made with heat-insulated complete, healthy and safe materials.
ROOF
ROOF SYSTEM It is produced with the help of specially shaped construction and carrier one-piece profiles, and it is made with 20 cm eaves and 36 cm high parapet. Rain water is discharged through corner columns.
ROOF INSULATION The 80 mm thick mattress is made of glass wool (14 kg/m³).
INTERNAL SURFACE COATING Inner surface ceiling covering PVC paneling is used (optional 8 mm concrete board can be used (inner surface ceiling covering PVC paneling is used in metropolitan cabins with WC).
EXTERIOR COATING 0.50 mm thick 27 mm *200 mm deep Natural Trapezoidal Galvanized Sheet
DOORS
EXTERIOR DOOR It is TSE certified white PVC joinery measuring 90*210 cm.
INTERIOR DOOR It is an American wooden door measuring 80*200 cm.
WINDOWS
WINDOW It is TSE certified white PVC joinery in 120 * 100 cm dimensions.
SILL PVC moldings are used on the inner edges of the windows.
PINE 4+9+4 double glazing is used.
DYES
EXTERIOR Exterior surfaces are painted in the desired color with silicone-based exterior paint.
DOOR CASES 1 coat Rapid primer painted.
METAL PARTS 1 coat of Rapid primer paint is applied.
ELECTRICAL INSTALLATION (Flush mounted)
SYSTEM Each room has a switch, a socket, and a telephone socket. In addition, spot luminaires are used for lighting at the four corners of the eaves.
CABLE Electrical power is 2000 W 220 Volts, 3x2.5 mm for sockets, 2x1.5 mm for lighting, TSE certified NYM cables are used.
LIGHTING FIXTURES TSE certified torus luminaire is used for lighting.
SOCKETS AND SWITCHES TSE certified materials are used.
SANITARY INSTALLATION
SANITARY WARE  TSE certified materials are used.
CLEAN WATER INSTALLATION TSE certified PPRC materials are used.
WASTE WATER INSTALLATION TSE certified PVC material is used.
EXTERNAL LINKS
It is the customer's responsibility to pour concrete 20 cm more than the cabin dimensions, install the cabin on the ground, and make electricity, clean water and waste water connections.
LIFTING FUNCTION
Containers can be lifted and lowered from four corners with lifting eyebolts and steel ropes.