METROPOL CABIN TECHNICAL SPECIFICATIONS |
PRODUCTION DIMENSIONS |
Can Be Specially Produced On Demand. |
HEIGHT |
2800 mm Parapet Included. |
METAL MATERIALS |
ST 37 |
BETOPAN |
TSE 634-2 |
GLASS WOOL |
TS 901 |
POLYSTREN FOAM |
TS EN 13163 |
TECHNICAL DATA |
EARTHQUAKE CONDITIONS |
1st degree |
CLIMATE CONDITIONS |
3. Climate Zone |
SNOW LOAD |
80 Kg/m² |
WIND SPEED |
80 Km/Hour (provided that it is fixed to the ground) |
EXTERNAL WALL TRANSMISSION COEFFICIENT |
K: 0.50 Kcal/m2hc |
ROOF TRANSMISSION COEFFICIENT |
K: 0.69 Kcal/m2hc |
BASE HEAT CONDUCTION COEFFICIENT |
K: 0.68 Kcal/m2hc |
CHASSIS LOAD CAPACITY |
200 Kg/m² |
BASE |
FLOOR COATING |
PVC Mineflo with 2 mm thickness is used as floor covering on 14 mm non-flammable Betopan boards as the floor covering. |
OUTER WALL |
SYSTEM |
It is made with carcass with the help of specially shaped profiles. |
EXTERIOR COATING |
The outer surface coating is optionally covered with 12 mm thick Taşonit or wood patterned concrete boards. |
INTERNAL SURFACE COATING |
The inner surface coating is 8 mm thick betopan (inner surface coating PVC paneling is used in metropolitan cabins with WC). |
WALL INSULATION |
40 mm thick, 10 kg/m³ polystyrene foam (EPS) with fire class E; It is made with heat-insulated complete, healthy and safe materials. |
INNER WALL |
SYSTEM |
It is made with carcass with the help of specially shaped profiles. |
INTERNAL SURFACE COATING |
The inner surface coating is 8 mm thick betopan (inner surface coating PVC paneling is used in metropolitan cabins with WC). |
WALL INSULATION |
40 mm thick, 10 kg/m³ polystyrene foam (EPS) with fire class E; It is made with heat-insulated complete, healthy and safe materials. |
ROOF |
ROOF SYSTEM |
It is produced with the help of specially shaped construction and carrier one-piece profiles, and it is made with 20 cm eaves and 36 cm high parapet. Rain water is discharged through corner columns. |
ROOF INSULATION |
The 80 mm thick mattress is made of glass wool (14 kg/m³). |
INTERNAL SURFACE COATING |
Inner surface ceiling covering PVC paneling is used (optional 8 mm concrete board can be used (inner surface ceiling covering PVC paneling is used in metropolitan cabins with WC). |
EXTERIOR COATING |
0.50 mm thick 27 mm *200 mm deep Natural Trapezoidal Galvanized Sheet |
DOORS |
EXTERIOR DOOR |
It is TSE certified white PVC joinery measuring 90*210 cm. |
INTERIOR DOOR |
It is an American wooden door measuring 80*200 cm. |
WINDOWS |
WINDOW |
It is TSE certified white PVC joinery in 120 * 100 cm dimensions. |
SILL |
PVC moldings are used on the inner edges of the windows. |
PINE |
4+9+4 double glazing is used. |
DYES |
EXTERIOR |
Exterior surfaces are painted in the desired color with silicone-based exterior paint. |
DOOR CASES |
1 coat Rapid primer painted. |
METAL PARTS |
1 coat of Rapid primer paint is applied. |
ELECTRICAL INSTALLATION (Flush mounted) |
SYSTEM |
Each room has a switch, a socket, and a telephone socket. In addition, spot luminaires are used for lighting at the four corners of the eaves. |
CABLE |
Electrical power is 2000 W 220 Volts, 3x2.5 mm for sockets, 2x1.5 mm for lighting, TSE certified NYM cables are used. |
LIGHTING FIXTURES |
TSE certified torus luminaire is used for lighting. |
SOCKETS AND SWITCHES |
TSE certified materials are used. |
SANITARY INSTALLATION |
SANITARY WARE |
TSE certified materials are used. |
CLEAN WATER INSTALLATION |
TSE certified PPRC materials are used. |
WASTE WATER INSTALLATION |
TSE certified PVC material is used. |
EXTERNAL LINKS |
It is the customer's responsibility to pour concrete 20 cm more than the cabin dimensions, install the cabin on the ground, and make electricity, clean water and waste water connections. |
LIFTING FUNCTION |
Containers can be lifted and lowered from four corners with lifting eyebolts and steel ropes. |